• Users Online: 307
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2016  |  Volume : 5  |  Issue : 1  |  Page : 7-13

Stress analysis in maxillary incisor following fragment reattachment: A finite element analysis


Department of Pedodontics and Preventive Dentistry, Bapuji Dental College and Hospital, Davangere, Karnataka, India

Correspondence Address:
Limaye Nandita Shrikant
Room No. 3, Department of Pedodontics and Preventive Dentistry, Bapuji Dental College and Hospital, Davangere - 577 004, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2277-4696.185188

Rights and Permissions

Objectives: To demonstrate stress propagation through three flowable composites used in fragment reattachment using finite element models. Study Design: It was a finite element analysis. Materials and Methods: Two permanent maxillary incisors were selected of which one was used as control. The test tooth was sectioned and reattached using simple reattachment technique. The groups were: Filtek Z350 (Group 1), G-aenial Universal Flo (Group 2), Esthet X-Flow (Group 3). Finite element models were created using cone beam computed tomography images of these teeth. Required physical properties of enamel, dentin, periodontal ligament (PDL), bone, flowable composites were fed into the software. Models were subjected to a load of 150N in a vertical direction. Analysis was done using ANSYS software wherein data were obtained in pictographic and numerical form (Von Mises' stresses [megapascal]). Results: Among flowable composites, maximum stress was created in Esthet X-Flow whereas least stress was observed in Filtek Z350. Maximum stress concentration occurred at the point of load application for flowable composite and enamel, at the point of load application directed in the cervical direction of the crown for dentin, in the apical region for PDL and the cervical bone area for bone. Conclusion: The study revealed that Filtek Z350 had superior tested properties and showed the least stress propagation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3309    
    Printed151    
    Emailed0    
    PDF Downloaded370    
    Comments [Add]    

Recommend this journal